Intended use

AquaMax Eco Classic 2500/3500/5500/8500/11500/14500/17500, referred to as "unit", may only be used as specified
in the following:
• For pumping normal pond water for filters, waterfalls and water courses.
• Operate in accordance with instructions.
• Operation under observance of the permissible water quality. (→ Water quality)
The following restrictions apply to the unit:
• Do not use in swimming ponds.
• Never use the unit to convey fluids other than water.
• Never run the unit without water.
• Do not use for commercial or industrial purposes.
• Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
• Do not connect to the domestic water supply.

Installation and connection

 A
W A R N I N G
Death or serious injuries from hazardous electrical voltage due to operation of this unit in a swimming pond.
• Never operate this unit in a swimming pond.
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
Aquamax Eco Classic 2500
Installation
Always place the unit below water level.
Place the unit horizontally on the ground ensuring its stable position.
Operating the unit in the pond
 B
The pump is in the pond. The return system, e.g. a pond filter, is connected to the pump outlet.
How to proceed:
 C
1. Screw the stepped hose adapter to the outlet.
2. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
– This reduces pressure losses.
3. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
Aquamax Eco Classic 3500/5500/8500/11500/14500/17500
Installation
The unit can be placed submerged or dry.
Always place the unit below water level.
Place the unit horizontally on the ground ensuring its stable position.