PLS
Properties
Optical data
Scan angle
Angular resolution
Protective field
Range (radius)
Reflectance of object
(diffuse)
Resolution
Safety category
DIN V 19250
EN 954-1
IEC/EN 61496-1
The EC type testing was performed in accordance with BIA test
recommendations which to a great extent correspond to the current
draft standard IEC 61496-3:1999
Warning field
Range (radius)
Reflectance at 15 m and 80 mm
object diameter
Safety category
Measuring range
Range (radius)
Reflectance
166
8 009 810/OA87/13-09-04 Operating Instruction • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved
Data
min.
type
180°
0.5°
1.8 %
50 mm
Requirement class 4
Category 3
Type 3
Type 3
20%
None
Graph
(see p. 67 of PLS TD)
GB
max.
1° by
pixel
blanking
1,5 m
Type 3
50 m
50 m