- EN -
Commissioning/start-up
N O T E
Prevent the pump from running dry. Otherwise the pump will be destroyed.
Only operate the pump when it is immersed.
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.
Series Eco 3000/4000: The pump will shut down after 10 attempts if the rotor is blocked or runs dry. Disconnect the
power plug! Remove the obstacle or „flood the pump". Following this, the unit can be restarted.
Aquarius Universal Premium Eco 3000/4000:
N O T E
Sensitive electrical components. Incorrect connection will destroy the unit.
Do not connect the unit to a dimmable power supply.
Aquarius Universal Premium 4000-12000:
The pump power can only be controlled by an OASE current management unit.
C A U T I O N
Risk of injury due to fast rotating components.
A temperature monitor switches the unit off automatically in the event of overload and on again once it has
cooled down.
Isolate the unit before starting any work.
Maintenance and cleaning
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
Isolate the device (disconnect from the power supply) before carrying out any work on it.
N O T E
Recommendation regarding cleaning:
Clean the unit as required but at least twice a year.
When cleaning the pump, pay particular attention to the cleaning of the impeller unit and pump housing.
Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
After cleaning, thoroughly rinse all parts in clean water.
12