BLOCKING/DISABLING IN THE SYSTEM

3.1. BLOCKING USERS

Any user can be temporarily blocked (e.g. when a user loses a card/tag or his access code is
revealed). When user's access is blocked their ID code or card/tag will no longer be accepted by the
system. The users will also not receive any SMS alerts or voice reports to their phone.
Only the system administrator or service technician can block a user. One method of taking away
access rights is by choosing Settings / Users / User / Bypass and selecting "Yes" on the LCD keypad.
Another option is to locally or remotely block a user through the J-Link software by clicking on the user
in the Settings / Users / User blocking column.
A blocked (disabled) user will be marked with a red circle until the blocking is cancelled.

3.2. BLOCKING DETECTORS

A detector can be temporarily blocked in a similar way a user can be disabled. A detector is blocked
when its activation is temporarily not desirable (for example a motion detector in a room with a pet or
disable a siren sounding). The system still performs diagnostics of tamper contacts and sends service
events however the alarm function is deactivated.
Only the system administrator or service technician can block a detector. It can be achieved by choo-
sing Settings / Devices / Bypass and selecting Yes on the LCD keypad. Another option is to use the
J-Link software by clicking on the detector in the Settings / Diagnostics / Disabled column. A blocked
detector is marked with a yellow circle until it is turned back on using the same procedure. A device
can be also blocked from MyJABLOTRON smartphone app.

3.3. DISABLING TIMERS

To temporarily disable automated scheduled events in the system, a timer can be disabled. Disabling
a scheduled event (e.g. unsetting the system from night guarding at a predetermined time) will prevent
execution of that event (e.g. while on vacation).
A timer can be disabled locally or remotely through the J-Link software by clicking on the section in the
Settings / Calendar / Blocked column. A disabled timer is marked with a red circle until it is turned back
on using the same procedure.
4.

CUSTOMIZING THE SYSTEM

4.1. CHANGING A USER ACCESS CODE

If the system is set up without prefi xed codes, only the system administrator and the service technician
can change the security codes. The system administrator can make changes from both the LCD key-
pad menu the J-Link software and MyJABLOTRON smartphone app. The code can be changed after
authorization by selecting Settings / Users / User / Code. To input a new code, you must enter edit
mode (the code will start fl ashing) by pressing Enter, enter the new code and confi rm by pressing Enter
again. After completing the changes, they must be confi rmed by choosing Save when the system
prompts you with "Save Settings?".
If the system is set up with prefi x codes, individual users can be allowed to change their codes from