The security of access codes, contactless RFID devices and remote controls:
A control panel enables each user to be assigned with one 4, 6 or 8-digit code and up to two
RFID tags for system authorization. User authorization is required during each manipulation ope-
ration via keypad, voice menu, a computer, web or mobile apps. Code length affects number of
possible combinations and therefore code security.
The number of code combinations depends on the configuration:
Control panel parameters
"Code with a prefi x"
enabled
"Code with a prefi x" and
"Duress access control"
both disabled
"Code with a prefi x"
disabled; "Duress access
control" enabled
26
TYPE DESCRIPTION
This code has access to sections and PG control rights assigned by an Administrator.
Users can add/delete their RFID tags and access cards and change their own telephone
numbers. Users can change their codes provided that the system uses Codes with pre-
fixes. It has permission to erase the alarm memory in assigned sections. Selected users
may have their access to sections limited by a schedule.
The number of User codes is limited only by remaining capacity of the control
panel. There is no code set by the factory defaults.
This code is allowed only to set a designated section and is allowed to control (ON/
OFF) PG outputs which require authorization. Users with this level of authorization are not
allowed to change their code and are not allowed to erase the alarm memory.
The number of Set codes is limited only by remaining capacity of the control
panel. There is no code set by the factory defaults.
This code allows the user to control programmable outputs with authorization only. This
applies to both switching on and off. Users with this level of authorization are not allowed
to change their code and are not allowed to erase the alarm memory.
The number of PG only codes is limited only by remaining capacity of the cont-
rol panel. There is no code set by the factory defaults.
This code is allowed only to trigger Panic alarm. A user of this code is not allowed to
change it or erase the alarm memory.
The number of Panic codes is limited only by remaining capacity of the control
panel. There is no code set by the factory defaults.
This is a code for a security agency. This level of authorization allows to set the whole
system. However, the guard code can unset the system only during alarm or after it
expired as long as the alarm memory is still active. A user of this code is not allowed to
change it or erase the alarm memory.
The number of Guard codes is limited only by remaining capacity of the control
panel. There is no code set by the factory defaults..
This code is designated to unblock the system after System blocking by alarm. A user of
this code is not allowed to change it or erase the alarm memory.
The number of Unblocking codes is limited only by remaining capacity of the
control panel. There is no code set by the factory defaults.
4 DIGITS
4
= 10
= (10.000)
4
= 10
– (Number of users – 1) = 10
≤ 10
4
– ((Number of users
– 1) * 3)
6 DIGITS
6
= 10
= (1.000.000)
6
– (Number of users – 1) = 10
≤ 10
6
– ((Number of users
– 1) * 3)
8 DIGITS
8
= 10
= (100.000.000)
8
– (Number of users – 1)
≤ 10
8
– ((Number of users
– 1) * 3)