2.1.2.1. ALARM SETTING
1. Authorize using
the keypad.
Sections which can be controlled
are lit up and the backlit indication
button will start fl ashing green.
While setting the alarm, if any detector is triggered (e.g. an open window) the system will react in one of
the following ways (based on the system confi guration):
:: Detectors will guard automatically after they switch to a standby mode (default setting).
:: The system will optically indicate triggered detectors with a segment fl ashing red for 8 seconds and
the system will set automatically once this period has expired.
:: Setting the section with triggered detectors is also possible by pressing the segment button on the
right side repeatedly. This way a user confi rms an intention to set the section with a triggered detector
(e.g. an opened window). Otherwise the section with the triggered detector will not be set.
:: A triggered detector will prevent the section from being set. This status is optically indicated by
a fl ashing red segment button. The detector preventing setting will be shown in the menu on the
keypad's LCD display.
An unsuccessful setting is indicated by the indication button fl ashing yellow ("Unsuccessful setting"
parameter must be enabled).
desired behavior of the system.
2.1.2.2. ALARM UNSETTING
1. When you enter the building
(triggering a detector with a "Delayed
zone" reaction), the system starts
indicating entrance delay with a
continuous tone and segment button
of the section in which the delayed
entrance has been triggered fl ashing
green.
Note: If the "Unset section by authorization only during entrance delay" parameter is enabled, then
mere authorization will unset such section where the entrance delay has been triggered.
2. Press the right button
(the one which isn't lit up) to set a
particular section. It is possible to
set more sections subsequently.
The delay between sections
selection must not be longer than
2 seconds.
Consult the installation with a service technician in order to program the
Authorize yourself using the
keypad
– the green indication light of the
authorization panel starts fl ashing.
2. Press the left segment button
of the section you want to unset.
3. The command
is executed
and the keypad acoustically indica-
tes the exit delay. The section is set
now, only the detectors with a "De-
layed Zone" reaction provide time
to leave the guarded area during
the exit delay. The segment button
of the set section turns red.
3. The command is executed
and the segment buttons turn green
to indicate unset sections
EN