jablotron JA-103K Manual Del Usuario página 36

Ocultar thumbs Ver también para JA-103K:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
Statuses of individual sections are indicated by status indicators A, B, C, D above the LCD display and
by the functions buttons. The control panel can be operated directly (setting or unsetting the alarm and
other automation functions) using function buttons on the keypad. The function buttons and the status
indicators A, B, C, D are colorfully backlit in order to clearly indicate the section status.
Authorization can be done by entering an access code on the keypad or using an RFID card/tag
assigned to a particular user. Each user can have one code and one RFID chip (a card or a tag). If the
users want to control multiple sections simultaneously, they must authorize themselves and then press
function buttons of the particular sections subsequently. This way the users can unset all sections (for
example the house and the garage) within one single authorization.
Structure and description of the internal LCD keypad menu
Administrator
or User
authorization
by the code or
RFID tag/card
34
::
GREEN
– Unset
::
CANCEL WARNING
INDICATION
SECTION
CONTROL
PG CONTROL
EVENT
MEMORY
SETTING
PREVENTED
FAULTS
IN SYSTEM
BYPASSED
DETECTORS
SYSTEM
STATUS
SETTINGS
DISPLAY
SETTING
MAINTENANCE
MODE
YELLOW
– Partially Unset
Allows you to cancel alarm/unsuccessful
setting indication in all sections to which
the user has access rights
Allows you to control the system's sections
to which the user has access rights and are enabled
in the internal settings.
Allows the user to control PG programmable
outputs depending on the user's permissions
and according to the internal settings.
Displays a detailed list of the event
memory.
Shows a list of triggered detectors preventing
setting the system, provided this option is activated
in the control panel confi guration.
Displays a list of all detectors indicating system faults
from sections to which the user has access rights.
Displays a list of all blocked detectors in sections to
which a user has access rights.
Shows system status (list of triggered detectors,
triggered tamper contacts, low batteries,
bypassing, etc.).
Allows editing of users and devices (only when
USB is disconnected).
Allows adjustment of keypad backlight intensity
and display contrast.
Allows the Administrator to switch assigned
sections to the Maintenance mode.
::
RED
– Set