C- INSTALLATION OF YOUR DEEP FREEZER
Selecting the place of installation
The operating environment of the product is very important for the smooth operation of your product. While selecting the operat-
ing environment,
Do not place your product exposed to outdoor environment (on the street, avenue, etc.).
Be careful for not obstructing lower shutter of the product with materials such as cardboard, box etc. for a proper cooling. (Picture
13)
Place the product at least one (1) meter away from heat resources (stove, radiator, electric heater etc.). (Picture 14-15)
Do not place it opposite to the air conditioner chutes, under fans and direct door and window openings. (Picture 16)
Do not expose to direct sunlight. Operation ratio will increase if sunlight comes to your cooler's glass. That means an increase in the
energy consumption.
Air intake and outlet must absolutely be fluent and free for proper operation of the compressor section of your product.
While approaching your product to the wall, be careful that there is a gap of 150 mm (15 cm) between the wall and back of your
cooler.
WARNING!
In very humid environments, ensure that floor and wall of the place where the freezer is located, is not affected by water;
against discharge water overflow danger.
In installations performed by Authorized Uğur Service, Authorized Uğur Service shall inform the consumer on the suitable
place for installation and make suggestion, but the consumer shall give the final decision on where the installation will be
made. This above mentioned process shall also be stated on the relevant installation form by Authorized Uğur Service. In
case of any loss arising from the place of installation of the product according to the final decision given by the consumer, all
responsibility related to such loss shall belong to the consumer.
Your product gives the best cooling performance according to the climate condition under the conditions given below. Therefore,
be careful that the temperature of the environment where your cooler will operate is at these levels.
EN
In Commercial Products:
Climate Class
Acceptable Ambient Temperature
Class 3
Between +16°C and +25°C 60% Humidity
Class 4
Between +16°C and +30°C 55% Humidity
Class 5
Between +16°C and +40°C 40% Humidity
Climate Class of your product is indicated on the
technical specification label on the product.
PICTURE 15
PICTURE 13
PICTURE 14
PICTURE 16
42
C- INSTALLATION OF YOUR DEEP FREEZER
Positioning
Possible placement positions:
1- In a way that the back side alone is opposite to the wall; be careful that there is a gap of 150 mm (15 cm) be-
tween the wall and your device. (Picture 17)
2- In a way that is place to a corner; when you place it to a corner, leave a gap of 150 mm (15 cm) behind. You can
lean the side, corresponding to the corner, to the wall.
The most important point to be considered in all cases of product placement is not to obstruct ventilation of the
compressor assembly.
Without exposing your product to any slope, place and operate it in a manner that it is on its feet or wheels.
The freer the compressor assembly ventilation is, the better the device will run.
PICTURE 17
43
EN