b7 Version number
Each of the digit positions (0-7)
is displayed in turn.
The example shows:
Version: 04 Date: 20.05.10
Select the position with the pushbuttons
b8 Service mode
000= control panel free, menu items adjustable
001= control panel locked, menu items not
adjustable
002= data output (accessory card)
Setting only possible if EMERGENCY STOP plug
(1, green) and photo cell (2, yellow) are
unplugged.
b9 Run counter (not adjustable)
Each of the digit positions (0-5)
is displayed one after another.
The example shows the value
8,000
Select the position with the pushbuttons
C0 Test mode for Magic-Door-Control (option)
Radio signal, maximum 15 seconds:
000= no signal
001= end position OPEN
002= end position CLOSED
003= run open
004= run close
005= standstill underway
007= error
008= obstruction
C1 Automatic closing from partial opening
secs and mins
000= OFF
001.010 keep-open time secs.*
(001 = 5secs... 010 = 50secs)
011..040 keep-open time min*
(011=1min... 040=30min) * plus warning time
C2 Partial opening in 5cm steps 000..100
C3 Lighting time, after motor running
000..060 (10sec. steps)
C4 Close after leaving the photo cell, 000..0.019, 0.5
s
C5 EMERGENCY stop input
000= automatic closing after EMERGENCY STOP
locked
001= closing time starts again after release

EMERGENCY stop

C6 Function connections
Connection 3
000
STOP
STOP
001
STOP
STOP
002
STOP
STOP
003
OPEN
CLOSE
Stop
STOP
C7 PARKING ASSISTANT operator light flashes
when door can be closed
000= OFF 001= ON
(only in connection with photo cell)
1)
If the added load (A5, A6) is >003 and/or the
automatic closing (b4, c1) is set to ON (>000), the door
may only be operated with an additional safety device.
12 / 214
04200510
01234567
and
.
000
008000
012345
and
.
000
1)
000
020
012
000
000
000
Connection 4
Partial opening
STOP
STOP
STOP
STOP
000
N000925 12/2010

19 Reset

ATTENTION: There is no longer any protection by
switching off the load after the reset. Teach the door
operator in again before re-commissioning. For this carry out
Teaching in the door operator (Chapter 15) .
Reset (saved values of the teach-in runs)
During one of the 3 status messages A, B or C (see Chapter
10) press the pushbuttons
for longer than 8 seconds and less than 10 seconds. The
indicator lamp flashes(rES), then the status message is
displayed; the reset is carried out.
The remote transmitters are not deleted.
Reset, factory setting
• Pull out the plug (1).
• During one of the 3 status messages A, B or C (see 10)
press the pushbuttons
longer than 12 seconds. The indicator lamp flashes slowly
at first, then quicker (rES). Then the status display
reappears, the reset is made.
The values shown under Programming (Chapter 18) are
set. The remote transmitters are not reset.

20 Attaching additional safety devices

Photo cell

Function: When the safety input is activated (opening the
contact) the operator stops and reverses as far as the OPEN
end position.
If the "automatic closure" function is also activated, following
the third successive obstruction message, the operator will
move to the OPEN end position and shut down.
Connection: Pull out plug with yellow bridge on the external
junction 2 and store it. Plug on safety device.
Safety rail, opto-sensor
connected by extension modules.
EMERGENCY stop
Function: If the external safety device is operated when the
door is moving (Contact opened), the door stops immediately.
Once the EMERGENCY stop contact has closed, the door
operator can be moved again with the next pulse.
Connection: Pull out plug with green bridge on the external
junction 5 and store it. Plug on safety device.

21 Additional connections

Additional lighting

Connection must be performed only by qualified electricians.
In addition to the operator light (40W), optional lighting of a
maximum of 60 W (no tubular fluorescent lamps) can be
connected to terminals 1 and 2.
Note: Some energy-saving lamps can interfere with the radio
signal.

External pulse input

An external pulse signal (e.g. wall button) can be connected
to terminals 14 and 15.
and Menu
simultaneously
and Menu
simultaneously for
warning light
and
Magic 1000