Malfunction
Device does not trigger.
Device does not trigger again.
The device does not trigger because the driving
pin does not produce a "click" sound.
Cartridge strip is not moved forward.
Firing power reduces considerably.
Piston severely distorted.
To maintain the optimum of reliability and security, we recommend to have the device inspected by a Würth
branch office or a customer service office authorized by Würth after two years at the latest.
Inspection location
18
Notes on troubleshooting
Remedy
Keep the device pressed against the fastening surface for 30 seconds.
Release the pressure and try again.
Keep the device pressed against the fastening surface for 30 seconds.
Release the pressure and try again.
Pull the cartridge strip manually to the next position and try again.
Check the safety device for correct functioning and try again.
Check the cartridge transport unit for correct functioning and try again.
Renew the piston spring.
Renew the piston.
Repeated inspection
Inspection date
Next inspection