OBJ_BUCH-946-004.book Page 22 Tuesday, July 29, 2014 4:02 PM
22 | English
Measure the distance A as for a length measurement. Pay attention that the line
segement A and the sought distance B form a right angle. Afterwards, measure
the distance C. The laser beam remains switched on between both measure-
ments.
Pay attention that the reference point of the measurement (e.g., the rear edge
of the measuring tool) is at the exact same location for both measurements.
Continuous Measurement (Tracking) (see figure E)
For continuous measurements, the measuring tool can be moved relative to the
target, whereby the measuring value is updated approx. every 0.5 seconds. In
this manner, as an example, you can move a certain distance away from a wall,
while the actual distance can always be read.
For continuous measurements, push button 6. The indicator for continuous
measurement (tracking) appears in the display
is indicated in the display. Repeated pushing of the measuring button 12 starts
the continuous measuring again.
Continuous measurement automatically switches off after 5 min. The last mea-
sured value remains indicated on the display. To cancel continuous measure-
ment, you can change the measuring function by pressing button 1, 3 or 5.
Deleting Measured Values
Briefly pressing button 7 deletes the last individual measuring value determined
in all measuring functions. Briefly pressing the button repeatedly deletes the in-
dividual measured values in reverse order.
Memory Functions
When switching off the measuring tool, the value in the memory is retained.
Storing/Adding Measured Values
If a value is already stored in the memory, the new value is added to the memory
contents, however, only when the measures of unit correspond.
As an example, when an area value is in the memory and the current measured
value is a volume value, the addition cannot take place. "Error" briefly flashes
in the display.
Subtracting Measured Values
Push the memory subtraction button 8 in order to subtract the current mea-
sured value from the memory value. As soon as a value has been subtracted,
"M" is indicated in the display and the "–" behind it briefly flashes.
1 609 92A 0K1 | (29.7.14)
After completing the second measurement, the dis-
tance B is calculated automatically. The last individ-
ual measured value is indicated at the bottom in the
display, while the final result B is indicated at the
top.
.
Press the measuring button 12 to initiate the mea-
suring procedure. Move the measuring tool until the
required distance value is indicated at the bottom of
the display.
Pushing the measuring button 12 interrupts the con-
tinuous measurement. The current measured value
Push the memory add button 2 in order to store the
current measured value – a length, area or volume
value, depending on the current measuring function.
As soon as a value has been stored, "M" is indicated
in the display and the "+" behind it briefly flashes.
Bosch Power Tools