Preventive maintenance
WARNING
performed by unauthorized
personnel may result in misplacing of
internal wires and components which
could
cause
recommend that all tool service be performed
by a Bosch Factory Service Center or Autho-
rized Bosch Service Station.
TOOL LUBRICATION
Your Bosch tool has been properly lubricated
and is ready to use. It is recommended that
tools with gears be regreased with a special
gear lubricant at every brush change.
CARBON BRUSHES
The brushes and commutator in your tool
have been engineered for many hours of
dependable service. To maintain peak
efficiency of the motor, we recommend every
two to six months the brushes be examined.
Only genuine Bosch replacement brushes
specially designed for your tool should be
used.
BEARINGS
Bearings which become noisy (due to heavy
load or very abrasive material cutting) should
be replaced at once to avoid overheating or
motor failure.
If an extension cord is
WARNING
necessary, a cord with
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used. This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-
wire extension cords that have 3-prong plugs
and receptacles.
NOTE: The smaller the gauge number, the
heavier the cord.
* Carrying Case/Bag
* Blades
Maintenance
Service
serious
hazard.
Accessories
WARNING
the power supply before cleaning or
performing any maintenance. The tool may
We
be cleaned most effectively with compressed
dry air. Always wear safety goggles when
cleaning tools with compressed air.
Ventilation openings and switch levers must
be kept clean and free of foreign matter. Do
not attempt to clean by inserting pointed
objects through openings.
BLADE HOLDER MAINTENANCE
Use dry compressed air to clean dust and
debris from the blade holder assembly on a
regular basis.
Periodically lubricate blade holder with a dry
lubricant such as graphite.
CAUTION
plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlorinated cleaning
solvents,
ammonia
detergents that contain ammonia.
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Tool's
Ampere
Cord Length in Feet
Rating
25
3-6
18
6-8
18
8-10
18
10-12
16
12-16
14
(*= standard equipment)
(**= optional accessories)
-11-
Cleaning
To avoid accidents always
disconnect the tool from
Certain cleaning agents
and
solvents
damage
and
household
Wire Sizes in mm
Cord Length in Meters
50
100 150
15
30
60
16
16
14
0.75 0.75 1.5
16
14
12
0.75 1.0 2.5
16
14
12
0.75 1.0 2.5
16
14
12
1.0 2.5 4.0
12
—
—
—
—
—
2
120
2.5
4.0
4.0
—
—