Reset To Default (Reset To Factory Defaults) - Seac GURU Manual Del Usuario

Ocultar thumbs Ver también para GURU:
Tabla de contenido
GURU
unlocked
12:30
DISPLAY
SYS SET
PC MODE
95%
01/01
Th
C
WARNING!!!
RESET ?
SETTINGS: NO
TISSUES: NO
EXECUTE
C
Confirm

Reset to Default (reset to factory defaults)

To navigate the menu, follow the instructions in the figure at left.
SETTINGS: Yes/No. Reset all menu items to factory defaults. The
SETTING command resets all menus and settings (MIX, Alarms, etc.). It
does not reset the diver's tissue saturation.
COMPASS
DEFAULT
TISSUES: Yes/No. Resets the diver's tissue saturation.
INFO
C
D
Do not reset the tissue saturation for ANY REASON if the device is
being used by the same person. This prevents GURU from running the
correct decompression calculation.
EXECUTE: Resets all items set to YES. (Select the EXECUTE function and
press the
B
Do NOT perform the tissue saturation reset (TISSUES=YES) if the device
YES/NO
will be used by the same person!
This can lead to the risk of accidents, including fatal ones.
The tissues can only be reset if the GURU device will be used by a
person who has not taken any dives in the previous 48 hours.
Any tissue reset is recorded permanently in GURU's dive logbook.
The user takes full and complete responsibility for a tissue saturation
D
reset.
YES/NO
m WARNING!
C
button to run the reset).
m WARNING! DANGER!
m WARNING!
English
23
Tabla de contenido
loading