Trouble Shooting/Corrective Action
Indication Cause
156
Lateral inclination greater than 10°
160
Angle value too large
162
The calibration was not carried out on a hori-
zontal surface or the calibration value is not
within a permitted range.
204
Calculation error
252/253 Temperature not within the permitted range
255
Receive signal too weak, Measuring period
too long, distance longer than 200 m
256
Receive signal too strong
257
Measuring error, ambient light too bright
260
Laser beam was interrupted during measure-
ment
ERROR
Hardware error
Warranty
For this Würth tool, we provide a warranty in
accordance with statutory/country-specific regula-
tions from the date of purchase (proof of purchase
by invoice or delivery note). Damage that has
occurred will be corrected by replacement or repair.
Damage caused by normal wear, overloading or
improper handling is excluded from the warranty.
Claims can only be accepted if the power tool is sent
undisassembled to a Würth branch office, your
Würth sales representative or a customer service
agent for Würth compressed-air and power tools.
Environmental Protection
Recycle raw materials instead of dispos-
ing as waste.
Machine, accessories and pakkaging should
be sorted for environment-friendly recycling.
The plastic components are labelled for categorized
recycling.
20
carried out by an authorized customer service agent
for Würth power tools.
For all correspondence and spare parts orders,
always include the article number on the type plate
of the machine.
For the current spare parts list of this machine, log
into the Internet under "http://www.wuerth.com/
partsmanager" or ask for a copy at your nearest
Würth branch office.
Corrective Action
Hold device level (not laterally inclined)
Measure angles to 45 ° max.
Carry out the calibration on a completely horizontal surface.
Conflict of units: Lengths miscalculated with areas and volume
Allow tool to cool down/warm up
Use target plate (accessory)
Use target plate (accessory)
Carry out measurement under other light conditions
Repeat measurement
Switch the tool off and on again; if required, several times. If the
error symbol does not go out, contact Würth customer service agent.
We declare under our sole responsibility that this
product is in conformity with the following standards
or
standardization
IEC 61 000-4-2, IEC 61 000-4-3, IEC 61 000-4-8
according to the provisions of the regulations
2004/108/EG.
08
Adolf Würth GmbH & Co. KG
P. Zürn
Subject to change without notice
Declaration of
Conformity
documents:
EN 55 022,
A. Kräutle