Menu Settings - Wurth Master WDM 201 Instrucciones Para El Manejo

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
WDM 201.book Seite 16 Dienstag, 18. November 2008 11:36 11
Stop/Rest Methods
B
The following stop/rest methods can be used with
the device:
Measurements from behind off of a level surface
Measurements from the front off of an edge (ad-
just measurement level!)
Measurements off an edge with the stop/rest an-
gle folded out rectangular
Measurements out of corners with the stop/rest
angle folded out completely
the zero point depending on the position of the
stop/rest angle.
During the measuring procedure, the optics
may not be covered.

Menu Settings

C
Push and hold this button to activate the
menu.
Pushing this button briefly; you are guided
through the functions.
These buttons guide you through the
setting options.
Press this button to leave the menu without
storing the settings.
Press and hold to store the new settings.
Units for distance measurements
Select the unit of measure and the indication accu-
racy:
Distance
Area
0.000
0
m*) 0.000
0
m
2
2
0.000 m
0.000 m
2
0.00 m
0.000 m
0.00 ft
0.00 ft
2
1
2
0'00''
/
0.00 ft
32
2
0.0 in
0.00 ft
0
1
/
in
0.00 ft
2
32
0.00 yd
0.00 yd
* Resolution 0,1 mm
Display Illumination
Display illumination dark.
1/6
Display illumination bright.
6/6
Offset
With the offset function, a defined value is automati-
cally added to or subtracted from the measured values.
16
.
.
. The device sets
Volume
0.000
0
m
3
3
0.000 m
3
0.000 m
0.00 ft
3
3
0.00 ft
3
0.00 ft
0.00 ft
3
0.00yd
Adapt the value with the
Pushing and holding the button fast-forwards the
value.
After storing, the respective symbol
indicated on the display.
Electronic Spirit Level
The spirit level is switched on.
The spirit level is switched off.
Calibrating the Inclination Sensor
– Place the measuring tool on a level surface.
– Press the
button for the first measurement.
– Rotate the measuring tool horizontally by 180°.
– Press the
button to confirm the position
change.
– Press the
button for the second measurement.
The inclination sensor is now calibrated.
Factory settings
Factory settings activated.
Factory settings deactivated.
NOTE: When activating the factory settings, the own
menu settings and memory contents are lost.
Camera Picture
The camera picture is in black/white.
The camera picture is in colour.
Setting the Audio Signal
The beep is switched on.
The beep is switched off.
Large Ranges (LR)
The mode is activated.
The mode is deactivated.
Switch the mode on for measurements over long
ranges and intense sunlight or very weak reflecting
target surface. For measurements in excess of 30 m,
longer measuring durations are possible; use a tri-
pod and initiate the measurement via the 23 button.
When switching off the measuring tool, the adjust-
ment is reset.
Units for inclination measurements
Inclination
± 0.0°
0.0 %
mm/m
in/ft
or the
button.
+
or
-
is
Tabla de contenido