SICK LE20 Instrucciones De Operación página 318

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 114
Chapter 9
3 1 8
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Technical data
Outputs
Outputs OSSD 1, OSSD 2
(The measurement data refers to
the connection at the equipment
plug)
TEST A, TEST B (inactive/active)
OVERRIDE LAMP
LAMP 1, 2
Operating data
Protection class
Enclose rating
Safety category
Compliance
ElectroMechanical compatibility
Ambient operating temperature
Storage temperature
Air humidity (Non condensing)
Vibration resistance
Impact resistance
Tab. 9-1: Data sheet for LE 20 (continued)
1
) The limit values for the voltage supply must not be overranged or
underranged.
The external voltage supply of the devices must bridge a momentary power
failure lasting 20 ms (to EN 60204). Suitable power supply units are available
from SICK as accessories (Siemens series 6 EP 1).
2
) The circuits to be connected to the inputs and outputs must have the
clearance and creepage distances specified in the relevant standards to
ensure reliable isolation to PELV (EN 60204, 6.4).
Operating Instructions
Safety Evaluation Unit LE 20
PNP, monitored and short-circuit protected
Switching current I
= 500 mA
max
Switching voltage U
= U
max
Switching capacity P
max
Inductive switching capacity P
Protective field clear U = U
Protective field broken U = 0 V
Residual current with sig. level "0" I = 0.1 mA
Max. capacitive load 200 nF with I = 50 mA,
2.5 µF with I = 500 mA
Test period test rate: 2 s
Test pulse width 150 µs ... 450 µs
U
– 3.5 V/0 V
B
Total current TEST A + TEST B < 10 mA
Max. capacitive load 10 µF
24 V DC, 1 ... 10 W
24 V DC, 1 ... 10 W
2
III
)
IP 20, IP 65 optional
EN 61496, type 2
EN 61496
EN 61000-6-4,
EN 55011 class A
–20 °C ... +60 °C
–25 °C ... +75 °C
15 ... 95 %
5 g/10 Hz ... 55 Hz to IEC 68-2-6
10 g/16 ms to IEC 68-2-29
8 008 685/Q913/2007-05-21
– 2.0 V with 500 mA
B
= 13.2 W
= 1 VA
max ind
max
Tabla de contenido
loading