4
Mounting
5
Electrical installation
8020347.14CS | SICK
Subject to change without notice
WTL16x-
WTS16x-
-xxxxxxx0
-xxxxxxx1
-xxxxxxx2
BluePilot blue: sensing range display
1
Press-turn element / Potentiometer / Teach-Button: adjusting the sensing range
2
LED indicator yellow: status of received light beam
3
LED indicator green: supply voltage active
4
Press-turn element: time function adjustment
5
Teach pushbutton: adjustment of light/dark switching
6
Mount the sensor using a suitable mounting bracket (see the SICK range of acces‐
sories).
Note the sensor's maximum permissible tightening torque of < 1,3 Nm.
Note the preferred direction of the object relative to the sensor,
(only applies to WTL16).
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
–
Male connector connection: Note pin assignment.
–
Cable: wire color
Only supply/switch on the voltage once all electrical connections have been estab‐
lished.
Explanations on connection diagram
Alarm = alarm output
OPERATING AND STATUS INDICATORS
-xxxxxx1x
-xxxxxx2x
1
2
4
3
6
1
2
4
3
5
1
2
4
3
(table 1
-
table
5).
3
-xxxxxx3x
1
2
4
3
6
1
2
4
3
5
1
2
4
3
see figure
11,
figure 12
5