12
Technical data
Sensing range max.
Light spot diameter/distance
Supply voltage U
B
Ripple
Current consumption
Output current I
max.
Max. response time
Switching frequency
Enclosure rating
6)
Protection class
Circuit protection
Ambient operating temperature
1)
Object with 90 % remission (based on standard white DIN 5033)
2)
16 VDC to 30 VDC, without load
3)
10 VDC to 16 VDC, without load
4)
Signal transit time with resistive load in switching mode. Deviating values possible in COM2 mode.
5)
With a light/dark ratio of 1:1 in switching mode. Deviating values possible in IO-Link mode.
6)
Pursuant to EN 60529
7)
Replaces IP69 K pursuant to ISO 20653: 2013-03
8)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
9)
Do not bend cables below 0°C.
12.1
Dimensional drawings
8020347.14CS | SICK
Subject to change without notice
4,1
20
2
1
7,8
3
5
Ø 12,9
7,7
6
16
Figure 11: Dimensional drawing 1,
WTL16 cable
Preferred direction of the target
1
object
Center of optical axis, sender
2
WTL16P
10 mm ... 500 mm
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
2)
< 50 mA
3)
≤ 100 mA
≤ 500 µs
4)
1000 Hz
5)
see table
1:
x4, xH, x5, xI: IP66,
IP67, IP69
7)
x9, xB: IP65
III
A, B, C, D
8)
–40 °C ... +60 °C
42
2
1
29,9
35,5
3
4
6
6,5
3
15
27,8
7
89
Figure 12: Dimensional drawing 2,
WTL16 male connector
TECHNICAL DATA
WTS16P
10 mm ... 750 mm
1)
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
2)
< 50 mA
3)
≤ 100 mA
≤ 1.4 ms
4)
350 Hz
5)
see table
1:
x4, xH, x5, xI: IP66,
IP67, IP69
7)
x9, xB: IP65
III
A, B, C, D
8)
–40 °C ... +60 °C
9)
42
4,1
20
29,9
52,9
17,5
4
5
15
M12
7,5
28
35,5
6
16
7
89
12
1)
9)
6
6,5
3
17