7
COMMISSIONING
10
xxxxxx2 xAxx-xxxxxx2 xAxx with Teach-Turn adjustment:
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.). Depend‐
ing on the requirements, the potentiometer can be used for fine-tuning (without pressing
the teach-in button).
Clockwise rotation: sensing range increased.
Counterclockwise rotation: sensing range reduced.
The sensing range can also be adjusted using just the potentiometer. We recommend plac‐
ing the object within the sensing range, see figure 8 for an example. Once the sensing
range has been adjusted, the object is removed from the path of the beam, which causes
the background to be suppressed and the switching output to change
and
table
4).
1
1...3 sec.
2
3
Figure 4: WTL16x-xxxxxx2xAxx, WTS16x-xxxxxx2xAxx red light, adjusting the sensing range
with press-turn element
(see table
2,
table 3
8020347.14CS | SICK
Subject to change without notice