10

Technical data

10.1

Technical specifications

en
The "Technical Data" chapter contains only an extract of the technical data of the sensor.
The complete technical data can be found on the homepage
Features
Sensing range
Min. sensing range
Sensing range max.
Emitted beam
Light sender
Type of light
Light spot size / distance
Electrical data
Supply voltage U
B
Ripple
Current consumption
Protection class
1)
Limit values
Reverse polarity protected U
Residual ripple max. 5 V
2)
Limit values
36
O P E R A T I N G I N S T R U C T I O N S | GSE20
Cleaning
NOTICE
Equipment damage due to improper cleaning.
Improper cleaning may result in equipment damage.
Only use recommended cleaning agents and tools.
Never use sharp objects for cleaning.
Clean the front screen at regular intervals and in the event of contamination with
b
a lint-free lens cloth (part number 4003353) and plastic cleaning agent (part
number 5600006). The cleaning interval essentially depends on the ambient
conditions.
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
connections
B
ss
www.sick.com
under the part number of the sensor.
GSE20G
0 m
120 m
GSE20G
LED
Visible red light
0.8 m / 20 m
DC
10 ... 30 V DC
1)
< 5 Vpp
≤ 30 mA
III
GSE20M
0 m
120 m
GSE20M
LED
Infrared light
0.8 m / 20 m
AC/DC
21.6 ... 253 V AC/DC
2)
< 10 %
≤ 50 mA, 24 V AC/DC
≤ 10 mA, 230 V AC/DC
II
8026847.1GHF/2022-07-06 | SICK
Subject to change without notice