Sensing range
Adjust the distance between the sensor and the reflector according to the corresponding
diagram [
see figure
0] (x = sensing range, y = operating reserve).
Operating reserve
y
100
10
6
5
1
0
1
2
(3.28)
(6.56)
After alignment is complete, move a non-transparent object into the path of the beam. Use
and Table 3 to check the function. If the switching output fails to behave in accordance
with Table 3, check the application conditions. See section Fault diagnosis.
Figure 10: sensing range areas
Table 4: Definition of sensing range
2
PL80A
1
PL40A
2
PL20A
3
P250
4
PL22
5
REF-Plus 3436
6
3
Sensitivity setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
3
2
4
3
4
5
6
(9.84)
(13.12)
(16.40)
(19.69)
(22.97)
Distance in m (feet)
GRL18(S)V
0.03 ... 7.2 m
0.03 ... 6.2 m
0.03 ... 3.8 m
0.03 ... 6.4 m
0.03 ... 2.2 m
0.06 ... 2.0 m
COMMISSIONING
1
x
7
8
(26.25)
6
9