10
TECHNICAL SPECIFICATIONS
10
Technical specifications
Sensing range (with reflector PL80A)
Sensing range max. (with reflector PL80A)
Light spot diameter/distance
Supply voltage V
S
Output current I
max.
Max. switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
2
Limit value; operation in short-circuit protection mains max. 8 A; residual ripple max. 5 V
5
With light / dark ratio 1:1
Signal transit time with resistive load
6
8
Reference voltage DC 50 V
10
A = U
-connections reverse polarity protected
V
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
11
IP68: according to EN 60529 (water depth of 10 m / 24 h).
IP69K: according to ISO 20653:2013-03.
12
GRL18(S)-xxxxxV
0.06 ... 6.0 m
0.03 ... 7.2 m
175 mm / 7 m
DC 10 ... 30 V
2
100 mA
1,000 / s
5
<0.5 ms
6
IP67, IP68, IP69K
11
III
8
A, B, D
10
-25 °C ... + 55 °C
ss
Subject to change without notice
8021183.16B5 | SICK