Technical Data; Dimensional Drawings - SICK ZSE18 Instrucciones De Operación

Ocultar thumbs Ver también para ZSE18:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
11

Technical data

Sensing range
Sensing range max.
Light spot diameter/distance
Supply voltage V
S
Output current I
max.
Max. switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature –40 °C ... +55 °C
1)
Limit value; operation in short-circuit protection mains max. 8 A; residual ripple max. 5 V
2)
With light / dark ratio 1:1
3)
Signal transit time with resistive load
4)
A = U
-connections reverse polarity protected
V
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
11.1

Dimensional drawings

Table 7: Dimensional drawings
13.6
(0.54)
M18x1
1
14.1
(0.56)
23
Figure 8: ZSE18-1xxxxx / ZSE18-Axxxxx
13.6
(0.54)
M18x1
1
14.1
(0.56)
Figure 10: ZSE18-2xxxxx / ZSE18-Bxxxxx, M8 connector
8021945 | SICK
Subject to change without notice
ZSE18-xxxxx1
DC 10 ... 30 V
1)
≤ 100 mA
1000 Hz
2)
≤ 500 µs
3)
IP67
III
A, B, D
4)
2 x Ø 3.5
(0.14)
2
3
(0.91)
2 x Ø 3.5 (0.14)
2
3
31.7
(1.25)
ZSE18-xxxxx3
ZSE18-xxxxx2
15 m
17 m
256 mm / 2 m //
1248 mm / 10 m
DC 10 ... 30 V
DC 10 ... 30 V
1)
≤ 100 mA
≤ 100 mA
1000 Hz
2)
1000 Hz
≤ 500 µs
3)
≤ 500 µs
IP67
IP67
III
III
A, B, D
A, B, D
4)
–40 °C ... +55 °C
–40 °C ... +55 °C
ss
13.6
(0.54)
1
Figure 9: ZSE18-2xxxxx / ZSE18-Bxxxxx, cable
13.6
(0.54)
1
Figure 11: ZSE18-2xxxxx / ZSE18-Bxxxxx, M12 connector
TECHNICAL DATA
ZSE18-xxxxx8
20 m
22 m
95 mm / 2m // 253
mm / 10 m
DC 10 ... 30 V
1)
≤ 100 mA
2)
1000 Hz
2)
3)
≤ 500 µs
3)
IP67
III
A, B, D
4)
4)
–40 °C ... +55 °C
2 x Ø 3.5 (0.14)
M18x1
2
14.1
3
(0.56)
21.9
(0.86)
2 x Ø 3.5 (0.14)
M18x1
2
14.1
(0.56)
3
31.7
(1.25)
11
1)
15
Tabla de contenido
loading

Tabla de contenido