Chapter
170
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice 8011036/TF94/2010-06-29
Technical specifications
Parameter
External protection
(operating voltage)
Switching current (relay
1)
outputs)
for switching
voltage
– 1 ... 60 V AC/DC
– 17 ... 30 V AC/DC
– 17 ... 230 V AC/DC
Switching load in
accordance with UL
External protection in
accordance with
IEC 60269-1
Usage category
according to EN 60947-
5-1
Resistance to vibrations
Mechanical service life
(relay)
Switching frequency
Time delay before
3)
availability
1)
If switching currents of > 300 mA are switched via the relay outputs, then it
will no longer be possible to safely switch low currents (T 10 mA) due to
possible damage to the gold plated contacts.
2)
In case of feedback circuit monitoring, the actuators must remain outside
the response range long enough, e. g. on opening the door, for the feed-
back circuit to close.
3)
After the operating voltage has been switched on and during the time delay
before availability, the relay outputs are switched off and the diagnostic
outputs are on LOW potential. The delay is indicated optically by the
flashing green LED STATE (15 Hz).
min.
0.4 A
1 mA
15 mA
15 mA
AC-12 60 V 300 mA 50 Hz
DC-12 60 V 300 mA
AC-12 30 V 6 A 50 Hz
AC-14 230 V 1,5 A 50 Hz
DC-13 24 V 1,2 A
acc. to EN 60947-5-2
2)
Operating instructions
T4000 Multi
Value
typ.
max.
300 mA
6000 mA
1500 mA
30 V AC,
Class 2
60 V DC,
Class 2
6 A gG
DC-12 30 V 6 A
6
10 x 10
0.25 Hz
10 s
12 s
8 A