6.4

A11 panel operation

Select the welding method using the switch (4)
S
Set the welding current using the knob (3), it's dial is scaled in Amps
S
Set the HOT START duration with knob (2)
S
Set the ARC FORCE value with knob (1)
S
6.5

A12 panel operation

Select the welding method using the switch (4)
S
Set the welding current using the knob (3), if switch (6) is set towards "A", then
S
value of current is displayed on display (7)
Set the HOT START duration with knob (2)
S
Set the ARC FORCE value with knob (1)
S
A12 panel incorporates remote current control receiver that cooperates with N02
transmitter. In oder to set the current remotely, the following steps must be
undertaken:
set switch (5) to "|
S
set demanded current with knob on N02 transmitter
S
put N02 on the work piece and make sure there is good electric contact
S
between work piece and N02 metal bottom
touch the metal disk on top of N02 with the electrode, hold it still untill N02
S
control lamp turns off (changes of current value during ttransmition should be
visible on A12 display)
6.6

Wired remote control operation

Connect wired remote control unit to socket (2) (wired remote control mode is
S
turned on automatically)
Set demanded current with knob on control unit (if A12 panel mounted, changes
S
of current value during transmition should be visible on A12 display)
6.7

Controls and connections

TM
6.7.1
Origo
Arc
1. Mains supply switch
2. Wired remote control socket
3. White lamp, power supply ON
4. Yellow lamp, thermal cut--out
5. "+" output terminal
6. "--" output terminal
7. TIG torch control socket
8. Panel (A11 / A12)
Arce
)))"
- - 9 - -