Stopping The Engine; Frequency Of Use; Ac Circuit Breakers - Westinghouse WGen20000 Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

OPERATION

STOPPING THE ENGINE

1. Turn off and unplug all connected electrical loads.
IMPORTANT: NEVER start or stop the generator with
electrical devices connected.
2. Let the generator run with no load for several minutes to
stabilize internal temperatures of the engine.
3. Turn the engine start switch to the OFF position.
Note: Alternately, if the generator is used infrequently,
turn the fuel valve to the OFF position to limit the
residual fuel remaining in the system. The engine
will stop when fuel in the carburetor and fuel line is
exhausted.

FREQUENCY OF USE

If the generator will be used on an infrequent or intermittent
basis (more than one month before next use), refer to
the Battery Maintenance and Storage sections of this
manual for information regarding battery charging and fuel
deterioration.

AC CIRCUIT BREAKERS

The circuit breakers will automatically switch OFF if there
is a short circuit or a significant overload of the generator
at each receptacle.
If an AC circuit breaker switches OFF automatically,
check that the appliance is working correctly and it does
not exceed the rated load capacity of the circuit before
resetting the AC circuit breaker ON.
The main circuit breaker controls total output of all outlets to
protect the generator from overload or short circuit.
Receptacle Circuit Breakers
ON
Push to Reset
OFF
16 | Westinghouse Outdoor Power Equipment, LLC
GENERATOR CAPACITY
Make sure the generator can supply enough continuous
(running) and surge (starting) watts for the items you will
power at the same time.
The total power requirements (Volts x Amps = Watts) of all
appliances connected must be considered. Appliance and
power tool manufacturers usually list rating information
near the model or serial number.
To determine power requirements:
1. Select the items you will power at the same time.
2. Total the continuous (running) watts of these items. This
3. Estimate how many surge (starting) watts you will need.
Main Circuit Breaker
Operating
Tripped
NOTICE
DO NOT overload the generator's capacity. Exceeding
the generator's wattage/amperage capacity can damage
the generator and/or electrical devices connected to it.
is the amount of power the generator must produce
to keep the items running. See the wattage reference
chart on the next page.
Surge wattage is the short burst of power needed to
start electric motor-driven tools or appliances such as a
circular saw or refrigerator. Because not all motors start
at the same time, total surge watts can be estimated by
adding only the item(s) with the highest additional surge
watts to the total rated watts from step 2.
Example:
Tool or Appliance
RV Air Conditioner (11,000 BTU)
TV (Tube Type)
RV Refrigerator
Light (75 Watts)
Coffee Maker
Total Starting Watts Needed
*Wattages listed are approximate. Verify actual wattage.
Running
Watts*
1010
300
180
Radio
200
300
600
2590 Total
Running
Watts*
Total Running Watts
Highest Starting Watts
Starting
Watts*
1600
0
600
0
0
0
1600
Highest
Starting
Watts*
2590
+ 1600
4190