Mounting the temperature sensor
Mark the temperature sensor cables
(e.g. E1, E2 etc.).
Mark the following insertion lengths, measured from ground
level, on the temperature sensor channels:
Height of the temperature sensor
Domestic hot water standby capacity (dimension a):
TTE 600 TA 1, approx.: 1050 mm
TTE 750 TA 1, approx.: 1100 mm
TTE 1000 TA 1, approx.: 1200 mm
Solar area/auxiliary heating (dimension b):
Approx. 550 mm for all types of storage cylinders
Domestic hot water standby capacity
To achieve an optimum standby capacity, set the following
temperatures on the control unit:
TTE 600 TA 1
TTE 750 TA 1
TTE 900 TA 1
* Suitable for heat pump
Fitting the thermal insulation
Fit the cylinder insulation as follows:
Install the base plate (2.03).
Fit the thermal insulation (2.0). Feed the temperature sen-
sor cable through one of the connector openings.
Close the thermal insulation with the zip.
Fit the top cover (2.04) and protective cover (2.05)
2.03
V03–03.2009
2
3
55 C°*
50 C°*
50 C°*
2.03
257 135
Insert the temperature sensors into the temperature sensor
channel as mentioned above in accordance with the draw-
ings.
4.1
4.1
Number of people
4
5
60 C°
55 C°*
55 C°*
2.05
2.04
2.0
After fitting the insulation, affix the classifica-
tion plate accompanying these installation
instructions in a prominent position on the
storage cylinder insulation.
en

Installation

4.1
4.1
6
7
÷
60 C°
60 C°
8
7