Installation Instructions – PMM / MSA Mesa
INSTALLATION
Please follow the installation instructions specific to the
catalog part that you ordered.
N
ote:
Care must be taken not to set lighting fixture down
on optical lenses or lift the fixture in the lens area.
Tools required
Allen key 3/16" , #2 Phillips head screw driver and torque
wrench.
A. Post Mount Single Luminaire (4" O.D. Pole Top
Complete with 3" O.D. Tenon, Tenon Length Range 3"
to 4" Only)
1.
Pull three leads from luminaire tenon fitter and supply
leads from the pole tenon.
2.
Connect supply wires to appropriate luminaire leads.
(Figure 1.)
Supply side ground wire to green luminaire lead.
●
Supply side neutral wire to white luminaire lead.
●
Supply side line voltage wire to black luminaire lead.
●
3.
Once connections are completely made, carefully push
all wires down into the tenon.
2
Cooper Lighting Solutions
IB525016EN
Installation instructions
Neutral Wire
Line Voltage
Wire
Ground Wire
Figure 1.
Tenon Fitter
3" Pole Tenon
4" Pole
Figure 2.
Street Side
Figure 3.
White
Black
Green
Arrow Mark on
the Dome