Ankara Twin - Mini Ankara Twin
English
in open air and therefore subjected to atmospheric agents;
near heat sources (direct sunlight, heating systems, incandescence lamps, etc.)
near air currents (near doors, windows, air-conditioning systems, etc.) that exceed
a speed of 0.2 m/sec.
Remove the supports in wood at the base (used for transport) and assemble the
adjustable feet (Rif. 8) positioning them so as to place the cabinet horizontally, aiding
yourself of a level (Rif. 9) to check proper alignment .
Before connecting the cabinet to the electrical line, make sure that the rating plate data
matches the characteristics of the electrical system to which the cabinet must be
attached.
For the cabinet to operate correctly, the room temperature and relative humidity must
not exceed the limits relative to climatic class 3 (+25°C; R.U. 60%) established by the
norms EN-ISO 23953 - 2 with which the counter has been tested
Do not displace the cabinet making leverage on the perimeter glass
panels, in order to avoid deformation of the support brackets (Rif. 13)
If the cabinet is displaced, re-check its levelling; an incorrect levelling
compromises operation of the cabinet.
11.Combining cabinets (Rif. 27 - Rif. 28) - specialized technician -
To combine two or more cabinets in channel, proceed as follows:
Disassemble the shoulders (if present).
Position the cabinets side by side
Join the risers and the brackets, using the screws supplied
Make sure the alignment pins are inserted in their provided seats.
CHANNEL COMBINATION KIT
Pos.
Denomination
7
E M6 nut
6
Screw TCEI M6x25
5
6x12 ZN washer
4
E M8 nut
3
Screw TCEI M8x50
(galvanized)
2
Screw TCEI M8x35
(galvanized)
1
Plug 4x30
12.Electrical connection - specialized technician -
BEFORE ANY OPERATION REMOVE VOLTAGE TO THE SYSTEM!
system must have a grounding connection!
The systems must be set up in accordance to the norms that regulate
manufacture, installation, use, and maintenance foreseen by the norms in
force in the country where the cabinet is installed.
ARNEG Spa rejects any responsibility toward the user and third parties for
damages caused by breakdowns or malfunctions of the systems arranged
upstream of the cabinet and for damages to the cabinet that stem from causes
directly ascribable to an electrical system malfunction.
The cabinet must be protected upstream with an automatic, omnipolar
magneto-thermal switch having adequate characteristics and which will serve
as the main line disconnecting switch.
It is the Client's responsibility to arrange the electrical power supply line up to the point
of connection to the cabinet. Sizing of the electrical power supply line must be
28
Pcs
Code
. Pos.
04230400
6
6
04711098
6
5
04480103
4
4
04230600
4
3
04711041
2
2
04711040
2
1
02940652 12
.
HEAD CASE
Denomination
6x12 ZN washer
Screw TCEI M6x25
Screw TCEI M6x30
E M8 nut
Screw TCEI M8x50
(galvanized)
Plug 4x30
The electrical
Pcs
Code
.
04480103
2
04711098
4
04711068
2
04230600
2
04711041
2
02940652 10
05060138 00 05/02/2013