12
Technical data
12.1
Electrical and mechanical data
Sensing range max. (with reflector P250F)
Light band dimensions / distance approx.
Minimum detectable object (MDO)
Suppression of objects
Minimum distance between sensor and reflector
Supply voltage U
B
Current consumption
Output current I
max.
Communication mode
IO-Link
Max. response time
Switching frequency
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
1)
We recommend using compound triangular reflectors or reflective tape to ensure reliable operation. Suitable reflectors and foils can be
found in the SICK accessories range. Use of reflectors with large-scale triple structures can negatively influence functionality.
2)
16 VDC to 30 VDC, without load
3)
10 VDC to 16 VDC, without load
4)
Signal transit time with resistive load in switching mode. Deviating values possible in COM2 mode.
5)
With a light/dark ratio of 1:1 in switching mode. Deviating values possible in IO-Link mode.
6)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
8022198.1BXN / 2021-05-26 | SICK
Subject to change without notice
TECHNICAL DATA
RAY10
0 ... 1.5 m
1)
37 * 12 mm / 1 m
≥ 5 mm
< 1 mm
300 mm
DC 10 ... 30 V
≤ 30 mA
2)
, < 50 mA
3)
≤ 100 mA
COM2
1.1
≤ 0.5 ms
4)
1000 Hz
5)
IP67
III
A, B, C, D
6)
-40 °C ... + 60 °C
O P E R A T I N G I N S T R U C T I O N S | RAY10
12
en
33