USE

CHECKING FOR LEAKS

After all connections are made, check all connections and fittings on the propane cylinder valve, and
regulator assembly for leaks with a water and soap solution.
To prevent fire or explosion while testing for a leak:
• Always perform leak test prior to lighting the griddle.
• Do not smoke while testing for a leak.
• Always perform leak tests outdoors in a well-ventilated area.
• Do not use any source of flame while testing for leaks.
• Do not use the griddle until any and all leaks are corrected.
• If you are unable to correct a leak, disconnect the propane supply and call a gas appliance service
dealer.
PERFORM LEAK TEST
• Prepare leak test solution by 50/50 ratio of liquid dish soap and water.
Total solution required is approximately 2 - 3 ounces (70 - 90 ml).
Put leak test solution in a spray bottle.
• Ensure the control knob is in the
• Connect the regulator assembly to the gas supply.
• Spray leak test solution on all gas carrying connections and fittings. Presence of bubbles at areas
of applied test solution indicates a gas leak. If leaks are detected or you smell or hear gas, shut off the
gas supply valve immediately and repair or replace the defective part. Do not use the griddle until
all leaks are corrected.
Only use the regulator assembly provided! If a replacement is necessary, please call
our customer service center. Do not use replacement parts that are not intended for this griddle.
ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED TO
PREVENT FIRE, DAMAGE AND/OR INJURY.