6 Commissioning
Without
Without
Without
Tab. 6
Mounting the extraction arm
EN - 12
9 Feed the extraction hood's electric cable through the
connecting tube from the bottom.
10Insert the extraction hood into the connecting tube and
rotate it once to secure it in place.
11 Place the clamp over the metal flange and attach
it loosely.
12 Slide the connector over the profile tube until the screw
holes are aligned and then secure the connector to the
profile tube using the screw. The electric cable must be
protruding out of the metal flange.
13 Connect the electric cable on the profile tube with the
electric cable of the extraction hood.
14 Use a cable tie to secure the connected cables on the
profile tube.
15 Trim any protruding ends of the cable tie.
xFUME FLEX
BAL.0733.0 • 2021-01-11