AL-KO 32.3 VLE CC Comfort Instrucciones De Uso página 14

Tabla de contenido
ALKO
Operator presence control
The machine is equipped w ith an operator presence
control which stops the machine when it is released.
/ \
Danger!
Do not deactivate the function of the operator pres-
ence control.
Rear flap
The machine is equipped with a rear flap.
Visual safety indicator
The visual safety indicator displays when the w ork
shaft is secured. The w ork shaft is secured correctly
when the green m ark is visible (5 m m ).
Assembly
Assemble the machine in accordance w ith the illustra-
tions (Figs. A, B).
/\
Important!
The machine is not allowed to be operated unless it
has been fu lly assembled.
Startup
/ \
Important!
Always perform a visual check prior to startup. Do
not operate the machine if the blade system and/or
the fastening parts are loose, damaged or worn.
■ Comply with working time regulations in force in
your country
Power cable safety
■ Only use rubber-sheathed cables with quality
H05RN-F acc. to DIN/VDE 0282 with a conductor
cross section of 3 x 1.5 mm2
■ The type designation m ust be marked on the
power cable. The plug and coupling socket must
be made from rubber or sheathed in rubber, and
be in accordance w ith DIN/VDE 0620
■ Only use a power cable w ith sufficient length
■ The power cable, plug and coupling socket m ust
be protected against splash water
14
(Fig. C, Fig. H)
■ Repairs on the power cable, plug and coupling
socket are only allowed to be carried out by au-
thorised specialist companies. A defective power
cable (e.g. w ith cracks, cuts, crushed or kinked
points in the insulation) is not allowed to be used
■ Protect the plug connections against m oisture
/ \
Danger!
Do not damage or cut the power cable.
If the power cable is damaged, im mediately discon-
nect it from the mains.
Electrical requirements
■ 230 V/50 Hz alternating current
■ M inim um cross section
■ Power cable = 1.5 mm2
■ M inim um fusing of mains connection = 10 A
■ Residual-current circu it breaker (RCCB)
■ M axim um tripping current = 30 mA.
Establishing the mains connection
1. Connect the coupling part of the power cable to
the plug on the safety pushbutton switch.
2. Coil the power cable into a loop and hook it into
the cable strain relief. Leave the loop long enough
fo r the cable strain relief to be able to slide from
one side to the other.
Danger!
Never operate the machine from mains sockets
which do not have a residual-current circuit breaker.
Setting the working depth
/ \
Important!
Only set the w orking depth if the m otor is switched
off and the blade shaft is stopped.
Set the w orking depth of the blade shaft at the dial
selector.
1. Tilt the scarifier backwards w ith the handlebar.
2. Push the tw ist switch down and turn it to level "2".
P o s itio n s on th e d ia l se le c to r:
1 - 5 = Setting the working depth (Fig. D)
J I W ith new blades, set the dial selector to posi-
tion 2 at most!
Translation of original user instructions
(Fig. E)
(Fig. D)
Tabla de contenido
loading

Este manual también es adecuado para:

G1401405

Tabla de contenido