4-Wire Cord Connections - Haier HDE5000AW Manual Para El Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ELECTRIC Dryer
4-Wire Cord Connections (US Models Only)
1. Remove the screws securing the terminal block access cover and the strain
relief mounting bracket located on the back of the dryer upper corner.
2. Install a UL approved strain relief into the power cord entry hole of the
mounting bracket . Finger tighten the nut only at this time.
3. Remove the green neutral ground wire from the green ground screw located
above the terminal block.
Typical Conductor
Receptacle
Typical 4
Conductor Cord
(HDE5000AW and HDE5300AW)
Black 240V
White Neutral
Red 240V
Green Ground
English