6- Now choose another button other than the first one and press;
7- Successfully configured control, perform a trigger test using both buttons.
Note: In 3rd Case, the button should not be pressed twice for confirmation.
Erasing the transmitters:
With the PROG switch equal to the image above, hold down the LEARN button
until the LED flashes quickly and releases.
13 - BASIC CENTER CONFIGURATION
NOTE: At each touch of the LEARN button the LED flashing is increased. This
process is incremental, that is, the panel adds the presses of the LEARN button,
when the menu being set comes to an end, the next LEARN pulse will return the
menu to the home position..
1. Check that the gate is engaged. If not, engage it.
2. After recording the control, make sure that the (tilting drive nut) is between the
limit switches, or on top of any of them with their respective (limit switch) LED on,
and the stops well adjusted.
3. If the limit switches are already in the correct positions just go to index 4,
otherwise if the limit switches are not already adjusted follow the steps below:
Turn the PROG switch to the position as shown below:
• Activate the previously recorded remote control, the control unit will operate
normally only at low speed and without recording path or torque.
ATTENTION!
• If the engine direction is wrong, the control unit will touch the stop and adjust the
direction automatically, so always leave the stops adjusted.
• After the limit switch adjustment is complete, turn the PROG switch to the (RUN
mode) position, and press the previously recorded remote control.
NOTE: During learning, the control unit automatically identifies whether or not
the machine has a limit switch.
After learning the path and torque, the control unit learns the voltage of the grid
where it was installed and does not allow it to be installed in another grid of diffe-
rent voltage (LED flashes 5 times when connecting to the grid).
64