6.3.2 With locking straps and without stops on the end
slat
If the roller shutter is fitted with locking straps (I) but without
stops on the end slat (K), the lower end limit is automati-
cally set, whereas the upper end limit must be set using the
control point.
Setting the upper end limit
1)
Place the roller shutter in the required upper end limit
position.
-
If necessary, adjust the position of the roller shutter
using the Up or Down buttons.
2)
Press the STOP/my and down buttons simultaneously:
The roller shutter begins to lower in one continuous
movement even after the STOP/my and Down
buttons have been released.
3)
Lower the roller shutter until it reaches mid-height.
4)
Briefly press the STOP/my button to stop the roller shut-
ter moving.
5)
Press the STOP/my button again until the roller shutter
moves up and down:
6)
Press the RTS control point PROG button to program the
first control point:
The roller shutter moves up and down briefly.
The end limit positions have been programmed.
6.3.3 With flexible straps and stops on the end slat
If the roller shutter is fitted with flexible straps (L) and stops
on the end slat (J), the upper end limit is automatically set,
whereas the lower end limit must be set using the control
point.
Setting the lower end limit
1)
Place the roller shutter in the required lower end limit
position.
-
If necessary, adjust the position of the roller shutter
using the Up or Down buttons.
2)
Press the STOP/my and Up buttons simultaneously:
The roller shutter is raised in one continuous move-
ment even after the STOP/my and Up buttons have
been released.
3)
Raise the roller shutter until it reaches mid-height.
4)
Briefly press the STOP/my button to stop the roller shut-
ter moving.
5)
Press the STOP/my button again until the roller shutter
moves up and down:
6)
Press the RTS control point PROG button to program the
first control point:
The roller shutter moves up and down briefly.
The end limit positions have been programmed.
6.3.4 With flexible straps and without stops on the end
slat
If the roller shutter is fitted with flexible straps (L) but without
stops on the end slat (K), the lower and upper end limits
must be set using the control point.