Accuracy Specifications; Speaker; Trigger Clamp - Bosch FSA 450 Instrucciones De Servicio

Ocultar thumbs Ver también para FSA 450:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
FSA 450
...10.
Hardware

10.7 Accuracy specifications

Accuracy data valid at 20°C to 25°C
LSB = least significant bit of analog to
digital converter
10.7.1 Oscilloscope
Channels 1, 2, 3, and 4:
-
±(3.5% x reading + 0.02DIV)
-
Input Range: ±200V
Frequency measurement:
-
±(0.01% + 0.02DIV)
10.7.2 Graphing Multimeter
Frequency accuracy
-
±(0.01% x reading + 3 LSB)
DC voltage amplitude
-
±(3.5% x reading + 1 LSB)
Robert Bosch GmbH
10.7.3 DVOM (DC voltage)
Range
Resolution
0.4V
0.0001V
4V
0.001V
40V
0.01V
400V
0.1V
10.7.4 DVOM (AC voltage)
Range
Resolution
0.4V
0.0001V
4V
0.001V
40V
0.01V
400V
0.1V
10.7.5 DVOM (Resistance)
Range
Resolution
400Ω
0.1Ω
4KΩ
0.001KΩ
40KΩ
0.01KΩ
400KΩ
0.1KΩ
4MΩ
0.001MΩ
40MΩ
0.01MΩ
10.8

Speaker

95 dBA at 10 cm

10.9 Trigger clamp

!
Close trigger clamp slowly. Do not snap
shut!
EN | 35
Accuracy
0.3% + 1 LSB
0.3% + 1 LSB
0.3% + 1 LSB
0.3% + 1 LSB
Accuracy
30 - 400 Hz
2% + 4 LSB
2% + 4 LSB
2% + 4 LSB
2% + 4 LSB
Accuracy
1% + 5 LSB
0.5% + 2 LSB
0.5% + 2 LSB
0.5% + 2 LSB
0.5% + 2 LSB
1% + 5 LSB
1 689 979 945 (28.07.2006)
Tabla de contenido
loading

Tabla de contenido