Electrical
Bathroom Installation
This built-in electric firebox must
be protected by a GFI circuit when
installed in an area where water is
present. If the unit is installed using
a receptacle, it must be readily
accessible.
This firebox is not watertight and must
be installed as to prevent water from
entering the unit. Install the unit away
from showers, tubs, etc. Keep towels
and other combustible materials 3 feet
(0.9 m) away from the front of the unit.
Permanent Heat Disable
The firebox heater can be permanently
disabled by removing the electronic
jumper on the main control board.
Disable the heater before any other
installation takes place.
To permanently disable the heater:
1.
Locate and remove the panel on the
top left of the unit.
2
. Pull out the electronic jumper
(shunt), on the left side of the screw
in the right corner of the board. The
label beside the jumper is "HT EN".
3.
Reinstall the previously removed
panel.
General Electrical
The installation of the built-in electric
firebox must comply with the applicable
Local and/or National Electrical Codes
and utility requirements. (See the
unit wiring diagram at the end of this
section.) Employ qualified personnel
where required by law.
1.
Allow 8" (20.3 cm) of service cable
for connecting power supply wire
to junction box on the unit when
installing and before finishing the
wall. Allow up to 4 ft (122 cm) of
service cable for connecting power
supply wire to junction box when
installing after finishing wall.
2
. Wire a dedicated, properly fused
circuit with a 15 A rating for the
appropriate voltage (120 V, 240 V).
3
. Feed the service cable through
the electrical cover on the back of
the unit and secure using a 1/2"
(1.3 cm) approved strain relief
connector.
4
. Remove the outer jacket and strip
the individual conductors 1/2"
(1.3 cm) from the end.
5.
Follow the following instructions for
your specific installation.
6
. Wiring inspection can be done from
the front of the unit: remove the
access panel, to the right of the
controls, to access the service cable
and wires from the unit.
9