Electrical
Direct Power Wiring (120 V)
All wiring must be completed prior to installing the built-in electric firebox.
Use 2-conductor wires with ground (3 wires total) from the power supply (breaker
panel) to the junction box on the built-in electric firebox.
WHITE - N
BLUE - NH
BLACK - L1
GROUND - G
To install 120 V direct power wiring:
1.
Pull out the 5 wires marked L1, L2,
N, NH, and G (black, red, white,
blue, and green).
2.
Connect N (white) and NH (blue)
from the built-in electric firebox to
the neutral wire from the power
supply.
3.
Terminate L2 (red) with a wire
connector (not included).
4.
Connect L1 (black) wire from the
built-in electric firebox to the L1 wire
from the power supply.
10
RED - L2
WHITE - N
BLACK - L1
GROUND - G
5.
Connect the G (green) ground wire
from the built-in electric firebox to
the ground from the power supply.
6
. Insert all the wiring back into the
built-in electric firebox and secure
with a cable clamp.
7
. Make sure all connections are tight.
120 V
POWER
SUPPLY
BREAKER
PANEL