Electrical
Direct Power Wiring (240 V)
All wiring must be completed prior to installing the built-in electric firebox.
Use 3-conductor wires with ground (4 wires total) from the power supply (breaker
panel) to the junction box on the built-in electric firebox.
WHITE - N
BLUE - NH
RED - L2
BLACK - L1
GROUND - G
To install 240 V direct power wiring:
1.
Pull out the 5 wires marked L1, L2,
N, NH, and G (black, red, white,
blue, and green).
2.
Connect N (white) from the built-in
electric firebox to the neutral wire
from the power supply.
3.
Terminate NH (blue) with a wire
connector (not included).
4.
Connect L2 (red) wire from the
built-in electric firebox to the L2
wire from the power supply.
WHITE - N
RED - L2
BLACK - L1
GROUND - G
5.
Connect L1 (black) wire from the
built-in electric firebox to the L1
wire from the power supply.
6.
Connect the G (green) ground wire
from the built-in electric firebox to
the ground from the power supply.
7
. Insert all the wiring back into the
built-in electric firebox and secure
with a cable clamp.
8
. Make sure all connections are tight.
240 V
POWER
SUPPLY
BREAKER
PANEL
11