6.2.2 Drilling without hammering
▶ Set the function selector switch to this symbol:
6.2.3 Drilling with hammering action (hammer drilling)
▶ Set the function selector switch to this symbol:
6.2.4 Positioning the chisel (only TE 30-AVR)
CAUTION
Risk of injury! Loss of control over the chisel direction.
▶ Do not operate the tool when the selector switch is set to "Chisel
positioning". Turn the function selector switch until it engages in the
"Chiseling" position.
▶ Set the function selector switch to this symbol:
▶ The chisel can be adjusted to 12 different positions (in 30° incre-
ments). This ensures that flat chisels and shaped chisels can always
be set to the optimum working position.
6.2.5 Chiseling (only TE 30-AVR)
▶ Set the function selector switch to this symbol:
6.2.6 Forward / reverse
▶ Set the forward/reverse switch to the desired direction of rotation.
▶ Do not operate the function selector switch while the motor is running.
Risk of damage!
7

Care and maintenance

WARNING
Electric shock hazard! Attempting care and maintenance with the supply
cord connected to a power outlet can lead to severe injury and burns.
▶ Always unplug the supply cord before carrying out care and maintenance
tasks.
Care
Carefully remove stubborn dirt from the tool.
Clean the air vents carefully with a dry brush.
Use only a slightly damp cloth to clean the casing. Do not use cleaning
agents containing silicone as they can attack the plastic parts.
Maintenance
WARNING
Danger of electric shock! Improper repairs to electrical components may
lead to serious injuries including burns.
▶ Repairs to the electrical section of the tool or appliance may be carried
out only by trained electrical specialists.