polarity.
4.- The capacitor value will appear on the LCD screen.
MEASURING INDUCTANCE
1.- Connect the red testing point to the jack signaled "H" and the
black testing point to the jack signaled "COM".
2.- Set the dial to H range. Then press L/C.
3.- Connect the testing points to the inductor to be measured.
4.- The inductor value will appear on the LCD screen.
Be sure to remove the coil from any magnetic fi eld, in order
Be sure to remove the coil from any magnetic fi eld, in order
to obtain an accurate measure.
to obtain an accurate measure.

MEASURING TEMPERATURE

Warning
Do not connect the thermo pair to energized circuit, in order to
avoid electrical shock.
1.- Set the dial to °C range.
2.- The room temperature will appears in the screen.
3.- Insert the thermo pair type "K" inside of the "COM" jack and
"°C", then make contact with the object to be measured with the
tip of the thermo-pair.
4.- The temperature value will appear on the LCD screen.

MEASURING FREQUENCY

1.- Connect the red testing point to the jack signaled "Hz" and
the black testing point to the jack signaled "COM".
2.- Set the dial to 20KHz range.
3.- Connect the testing points to the circuit to be measured.
4.- The frequency value will appear on the LCD screen.
The reading it's only available using voltages higher than
The reading it's only available using voltages higher than
10Vrms, but the accuracy is not guaranteed.
10Vrms, but the accuracy is not guaranteed.
In noisy environments, it is preferable use cable for small
In noisy environments, it is preferable use cable for small
signals.
signals.

MEASURING DIODES

1.- Connect the red testing point to the jack signaled "V" and the
black testing point to the jack signaled "COM".
2.- Set the dial to
range.
3.- Connect the red testing point to the anode and the black
ENGLISH-11