9.1) CHARGE CARD (Optional ACCESSORY):
The unit is equipped with a power transformer that can
provide the motor's power requirement and that of the
electronic card when it is all powered directly by the mains.
If you want the system to continue working in the case of
a power cut then you have to add a suitable battery and
relative battery charge card.
The battery recommended can be placed inside the unit
and connected to the two terminals on the battery charge
card while the latter is plugged into the connector on the
unit.
9.2) "PER" CARD (Optional ACCESSORY):
The unit already has all the functions used in a normal installation but to meet the demands of use in particular installations
NICE has designed an optional card "PER" used to add new functions like traffic light signalling, courtesy light, lock, Photocell2,
partial opening of the two gates, and so on.
9.3) "RADIO" CARD (Optional ACCESSORY):
There is a connector in the unit for plugging in a radio card used to act on the STEP-BY-STEP input and thus control the unit
remotely by means of a transmitter.

10) MAINTENANCE:

The card, being electronic, needs no particular maintenance. However check periodically, at least twice a year, the perfect
efficiency and adjustment of the device that controls maximum motor force and, if necessary, adjust with the trimmers.
Check effectiveness of the safety devices (photoelectric cells, pneumatic edges, etc.) and correct functioning of the flashing
light.
10.1) INFORMATION ON MEASURES TO PROTECT THE ENVIRONMENT:
This product is made with different types of recyclable materials.
Inquire about recycling or disposal methods of the product, complying with the current local laws.

10.2) TECHNICAL SPECIFICATIONS:

Mains power
Battery power
Max current to motors
Max. accessory 24 Vdc and photocell test outputs power
Max. photocell test outputs power
Max flashing light power
Max gate open power indicator power
Pause time
Working temperature
Fig.: Fitting the optional batteries.
: 230 Vac + – 10%, 50-60Hz
: 21 ÷ 28 Vdc
: 5A
: 500mA
: 300mA
: 25 W (24 Vdc)
: 2 W (24 Vdc)
: from 1 to 1023 seconds
: -20 ÷ 70 °C