QUICK GUIDE

Do not install the unit unless you have read all the instructions through at least once!
Do not install the unit without the "Mechanical travel stops"!
Once the gearmotors, control devices (key selector or push button panel) and safety devices (emergency stop, photocells,
sensitive edges and flashing lights) have been installed, connect the unit as illustrated in the following diagram:
If the gate has only one motor, connect it to motor 2 output on the unit and cut the jumper; leave the terminals of motor 1 and
relative encoder free.
Turn the unit on and check that voltage between terminals 1-2 is 230 Vac and 24 Vdc between terminals 28-29. The LEDs on
the active inputs should be on and the OK LED should flash at 1-second intervals. The encoder LEDs signal each movement
of the 2 motors.
Check movement direction by pressing the CLOSE button on the card: Wait for motors 1 and 2 to start in closing (motor 2
starts after motor 1 has finished the manoeuvre).
Should either or both motors start the opening manoeuvre, reverse motor connections (terminals 7-8 or 9-10).
Activate the automatic distance search by setting the dip switches as indicated:
1 2 3 4 5 6 7 8 9 10
Press the CLOSE button on the card and wait for the automatic distance search procedure to be carried out.
Once finished, set the PROGRAMMING dip switches OFF and the FUNCTIONS dip switch as required (ON activates the
function)
Switch 1-2 :
Switch 3
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
Switch 9
Switch 10
In the automatic functioning mode, pause time is set at 30 seconds (Switch 2 ON). To change it see Chap. 6.7
Adjust the 2 amperometric trimmers until the triggering thresholds of the anti-crush clutch are reached, as required by law.
20
CHARGE CARD
MOTOR 1
AMPEROMETRIC
PROTECTION
F3
F2
COMMON
MOT 1
MOT 2
F1
M
M
Switch 10 "OFF" recommended
for "PLUTO"
(Slowing down during closing
manoeuvres short)
11 12
Off Of
= "Hold to Run Control" Functioning
On Of
= "Semiautomatic" Functioning
Off On = "Automatic" Functioning ( Automatic Closing )
On On
= "Automatic + Close Always" Functioning
On
= Condominium Functioning ( Not available in the Manual mode )
On
= Preflashing
On
= Water hammer
On
= Closes immediately after Photocell if in Automatic or closes after semiautomatic Photocell
On
= Photocell1 safety also in opening
On
= Photocell test activation (only with photocells connected to terminals 23..27)
On
= CLOSE becomes Pedestrian Open
On
= Courtesy light on flashing light
RADIO CARD
MOTOR 2
AMPEROMETRIC
OPEN
PROTECTION
AP
FUNCTIONS
DIP SWITCH
(1...10)
>> <<
LED
"OK"
CH
MICROPROCESSOR
CLOSE
"PER" CARD
ENCODER LED
INPUT LED
M1 M2
1 2 3 4 5 6 7 8 9 10
AERIAL
2ND RADIO CH
PROGRAMMING
DIP SWITCH (11-12)
Switch 10 "ON" recommended
for "METRO"
(Slowing down during closing
manoeuvres long)
11 12