4) TRAVEL LIMITS:

Once you have reached this point of the installation you can now set the travel limits within which the gate has to move. As
described in the introduction, the unit has a position control system that works with a movement encoder. This system can
constantly control the position of the gate.
Of course the internal logic has to be instructed as to the distances within which movement must occur; these distances are
shown in the following drawings as well as their meaning.
Fig. 2A
DISTANCE "0"
Distance "0" is the point in which the two gates are when closed (in line),
coinciding with the mechanical stop in closing.
Fig. 2B
DISTANCE "S"
Distance "S" is the point the gate has to reach moved by the 2nd motor in
opening before the gate moved by the 1st motor can start.
This is used if the gates could get stuck when opening or to have a safety
margin in closing, specified by law.
Distance "S" can also be close to distance "0" in which case both motors
start together.
Fig. 2C
DISTANCE "A"
Distance "A" is the point in which both gates are open to the extent
required (NOT necessarily coinciding with the mechanical stops in
opening).
Fig. 2D
DISTANCE "1"
Distance "1" is the point in which both gates are open to the maximum
extent coinciding with the mechanical stops in opening.
GB