Intended Use; Safety Advice - BGS technic 6750 Manual De Instrucciones

Tester de bomba de agua
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

COMPONENTS
A Gauge (0-15psi)
B Rubber pipe seals x2
C Blanking plugs x2
D Pipe connector body (two-piece)
E Hose, Ø 6 mm, lenght 2 m
F Male hose connector

INTENDED USE

The Water Pump Tester is made for testing the function of mechanically driven cooling system water
pumps in situ, while the engine is running. This tester gives an effective indication of the coolant flow
by measuring the smaller pressure rises that occur due to the coolant flowing around the block. This
product can help in identifying pump issues due to damaged impellers, seizing impeller shafts and
excessive water pump belt or drive slippage. A lot of current pump impellers are made of plastic and
can break up external leaks which can't be visible. Therefore this kit is to help identify these issues
prior to stripping the engine thus making a more effective and less time consuming.

SAFETY ADVICE

 Engine must under cold condition before conduct testing.
 Hand and eye protection must be wear.
 Be very careful when working with hot, pressurized cooling systems; there is a high risk of
serious scalding.
 Keep this test set clean and in good condition; do not use tester and hose adaptors if
damaged.
 Always refer to the manufacturer's service or diagnostic instructions to establish the correct
procedure. These instructions are provided as guide only.
OPERATING
Pre-test requirements:
 Engine must under cold condition
 Thermostat fitted and closed
 Coolant level correct with no air locks
 Safety care must be follow
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Water Pump Tester
Tel.: 02196 720480
Fax.: 02196 7204820
BGS 6750
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed