Control gate delayed - button with N.O. contact.
I01: FUNCT=3; r01: LIFE=1; DLY=30.
Pedestrian gate control - button with N.O. contact.
2-channels time switch with N.O. contact and impulsive mode.
The irrigation is activated for 30 minutes - I03: FUNCT=2; r03: LIFE=1800.
The outdoor lighting is activated for 12 hours - I04: CH2: FUNCT=2; r04: LIFE=43200.
4-channels transmitter:
- Key 1 (gate): F00; CH:01; CH02; CH03; CH04.
- Key 2 (pedestrian gate): F00; CH01; CH:02; CH03; CH04.
- Key 3 (irrigation system): F01; CH01; CH02; CH:03; CH04.
- Key 4 (Outdoor lighting): F01; CH01; CH02; CH03; CH:04.
PUSH
TO OPEN
PUSH
TO OPEN
I02: FUNCT=0.
CANALE 1
CANALE 2
COMUNE
POWER SUPPLY
Power supply.
12-24 Vdc-Vac
DISPLAY
20 21
UP
DOWN
MENU
OUT1
OUT2
OUT3
OUT4
+
-
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19
Outdoor lighting
Irrigation system
Electrical lock
pedestrian gate
Gate