4.1.6 rtime - OUTPUT PARAMETERS
In this sub-menu, for each relay (r01, r02, r03 o r04) it is possible to change the activation duration (LIFE) and the output delay
time (dLy).
To change the parameters, please follow the procedure below:
4.1.7 def - PARAMETERS RESET
By accessing the item def it is possible to restore the default values of the receiver. This reset does not delete the password and the
transmitters registered in the memory except for the parameters of the default transmitter.
In order to proceed with the reset, move to the item def and then confi rm with a long pressure of the MENU button. Keep pressed
until the display shows the value 0, then release the button. Keep pressed again the MENU button: a countdown starts d80, d79, ...,
d01, d00. Once the countdown ends, the reset has successfully been performed, and the display shows
4.2 Modif - TRANSMITTER PERSONALIZATION
By accessing the item ModiF it is possible to customize the transmitters in the memory.
In order to proceed with the change, move to the item Modif, and then confi rm with a long pressure of the MENU button.
Keep pressed until the display shows the fi rst position occupied by a transmitter (e.g. p0.0.0), then release the button. The positions
of the memory occupied by a transmitter are indicated by the presence of a point between the digits (for example P0.0.1).
The default transmitter, used during the learning (see section 3.1), is indicated in the memory as Pdef: it is possible to change its
characteristics as for any other remote control, but it cannot be moved/deleted/enabled.
Pdef is located before the position P000.
Use the UP (+) and DOWN (-) buttons to choose the desired transmitter, then confi rm with a long pressure of the MENU button. To
know the location of a specifi c transmitter, use the function SEE (see section 4.4) of the receiver.
Once the transmitter is confi rmed, a sub-menu opens, where it is possible:
6-1620020
rev.0
Go to the menu item rtime.
Press and hold the MENU button
until the display shows:
or
Select the output with the UP (+) and DOWN (-) buttons of the receiver.
Press and hold the MENU button until the display shows:
Select the desired parameter with the UP (+) and DOWN (-) buttons.
Press and hold the MENU button until the parameter blinks.
Set the desired value using the UP (+) and DOWN (-) buttons.
Confi rm the change with a long pressure of the MENU button
ITA
ENG
27/10/2015
The display shows:
or
or
The display shows:
o
FRA
ESP
DEU
POR
.