MENU
PARAMETERS FOR OUTPUTS
Sub-menu where you can:
rtIme
- set the activation time of the output with the Timed function or
Timed+Delay function (LiFE);
- set the delay time for the Timed+Delay function (dLy).
RESET OF THE PARAMETERS
def
It restores the receiver to default settings.
4.1.1 PWD - PASSWORD
The menu of the receiver can be protected by a password that will be requested at every login attempt.
This is shown in the display with P0000 and the fi rst digit blinking. To change the digit you can use the UP (+) and DOWN (-) buttons.
To move to the next digit press brie• y the MENU button. At the end of the procedure, if the password is correct you will enter the
menu, otherwise the display will show: P Err.
After 1 minute of inactivity the password will be re-enabled.
ATTENTION: it is not possible to delete a forgotten password. You will need a recovery procedure by the manufacturer.
4.1.2 Heyb - LEARNINGS
It is possible to enable or disable all the learnings. These are the only active functionality that does not require a password (if
enabled): in this way you add a further degree of protection to the receiver.
4.1.3 HIde - HIDDEN KEY (only with biroL coding)
It is possible to enable or disable the hidden button of the transmitters. This button allows you to enter the sequential learning/
delete the remote control.
4.1.5 Input - WIRED INPUTS PARAMETERS
It allows to associate to each wired input an output function.
There are 4 different functions:
- 0: Dead Man;
- 1: Step by step;
- 2: Timed;
- 3: Timed + Delay.
To change the parameter please follow the procedure below:
Select the desired function with the UP (+) and DOWN (-) buttons of the receiver.
8/20
DESCRIPTION
Go to the menu item Input.
Select the wired input using the UP (+) and DOWN (-) buttons of the receiver.
or
Select the wired input using the UP (+) and DOWN (-) buttons of the receiver.
Press and hold the MENU button
Press and hold the MENU button until the parameter blinks.
Confi rm the change with a long pressure of the MENU button.
ITA
ENG
The display shows:
The display shows:
or
or
The display shows:
until the display shows:
FRA
ESP
DEU
SELECTABLE
VALUES
DEFAULT
min-max
LiFE
LiFE
1-65535
dLy
dLy
0-255
POR
6-1620020
rev.0
UNIT
5
s
2
27/10/2015