Troubleshooting Guide; Care And Cleaning - American Standard Cadet 2794.709 Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Problem/Indicator
No ush or delayed ush
a. No batteries
b. Low battery in Flush Control or Hand Sensor Module.
c. Incorrect water level in tank
d. The Flush piston or lift rod are stuck.
e. No water in the tank
f. Toilet is clogged
g. Touchless hand swipe was too fast
h. Touchless hand swipe was not in sensor detection area
i. Water supply valve closed
j. Supply line blocked
k. Sand or debris lodged in lter screen
Leaking
a. Incorrect water level
b. Debris on sealing surface
c. Loose Shank Nut
d. Re ll water level is too high
e. The re ll tube is not installed properly.
Partial Flush
a. Re ll tube is not installed in the Over ow Tube
b. Incorrect water level
c. Manual Flush Button not fully depressed
Unintended Flush
a. Motion or object in sensor area
Manual Button not working
a. Manual Button is not depressed completely
b. There is no water in the tank
c. Incorrect water level
Hand Sensor Module ashes
a. Indicates battery power is low in Flush Control Module in tank
slowly 12 times
Hand Sensor Module ashes
a. Indicates battery power is low in Hand Sensor Module
quickly 5 times
Toilet leaks
a. Poor supply line connection
b. Poor bowl to tank/ oor connection
Toilet bowl rocks
a. Wax ring not fully compressed
after installation
b. Floor not level
a. The Flush Control Module in tank is not connected properly.
The Hand Sensor Module
can light up by sensing,
b. The codes of the Hand Sensor Module and Flush Control Module
but does not ush
are not matched or synchronized to each other.
c. The battery pack in the Flush Control Module may not be
orientated correctly.

CARE AND CLEANING

When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth.
WARNING: Do not use in-tank cleaners. These products can seriously corrode fittings in the tank. This damage can
cause leakage and property damage. American Standard shall not be responsible or liable for any damage
caused by the use of in-tank cleaners.

Troubleshooting Guide

Possible Cause
a. Install 4 alkaline AA batteries to the Flush Control Module and 3 AAA batteries to the Hand Sensor Module.
b. Follow procedure for low battery indication of Hand Sensor or Flush Control Module.
c. If water level is too low or too high, ush performance is affected. Fill water in the tank to the correct
level, as speci ed on the back of the tank. See "Water Level Adjustment" procedure.
d. Check if the piston or lift rod moves freely.
e. Fill the tank with water to the level speci ed on the label on the back of tank.
f. Lift toilet lid and disconnect "Flush Control Cable" from Battery Pack/Flush Control Module. Unclog toilet.
Press "Manual Flush Button" to clear trap way and con rm trap is clear of clog. Reattach 'Flush Control
Cable".
g. Initiate a slightly slower hand swipe within the sensor area.
h. Sensor detection area is directly in front of the sensor face and up to 2 inches away from the surface.
i. Open valve and allow water to ll tank.
j. Shut off water supply, disconnect supply line and inspect all gaskets and washers.
Reassemble.
k. Shut OFF water supply to toilet. Follow procedure for "Cleaning Flush Valve In-Line Filter".
a. If water level is too low or too high, ush performance is affected and leaking may occur.
Fill water in the tank to the correct level, as speci ed on the label on the back of tank.
b. Remove debris on sealing surface causing the leak.
c. Tighten the Shank nut to eliminate the leak.
d. Leaking occurs through the over ow tube due to the Fill Valve oat setting too high. Lower the oat
setting until the Fill Valve re lls to the correct water level. See "Water Level Adjustment Procedure".
e. Adjust re ll tube and ensure end of tube is above water line.
a. Connect the re ll tube to the Over ow Tube.
b. If water level is too low or too high, ush performance is affected. Fill water in the tank to the correct
level, as speci ed on the label on the back of tank. See "Water Adjustment Procedure".
c. Press the Manual Flush Button in further.
a. Remove item from the sensor activation area.
a. Press the Manual Flush Button in further.
b. Fill the tank with water to the level speci ed on the label on the back of tank. See "Water Adjustment Procedure".
c. If water level is too low or too high, ush performance is affected. Fill water in the tank to the correct
level, as speci ed on the label on the back of tank. See "Water Adjustment Procedure".
a. Replace batteries in Flush Control Module in tank.
a. Replace batteries in Hand Sensor Module.
a. Remove supply line, inspect and reconnect. Replace supply line if leak continues.
b. Review Step 2 through 8 of installation procedure.
a. Retighten bowl-to- oor knobs.
b. Use toilet shims and/or place a bead of caulk around the base of the toilet.
a. Ensure wire from Flush Control Module to Flush Valve Body is fully connected.
b. Install Hand Sensor Module batteries within 3 minutes after installing Flush Control Module batteries to
allow codes to match or syncronize.
c. Orientate the batteries in the battery pack.
- 7 -
Corrective Action
7302484-100R1 10/20
Tabla de contenido
loading

Este manual también es adecuado para:

Cadet 2989.709Cadet 215aa.709

Tabla de contenido